Skip to main content

Refrigeration engineering (2 cr)

Code: MI00DR69-3003

General information


Enrollment
08.04.2024 - 21.04.2024
Registration for the implementation has ended.
Timing
02.09.2024 - 20.10.2024
Implementation has ended.
Number of ECTS credits allocated
2 cr
Local portion
2 cr
Mode of delivery
Contact learning
Unit
Department of Logistics and Marine Technology
Campus
Kotka Campus
Teaching languages
Finnish
Seats
12 - 40
Degree programmes
Degree Programme in Marine Engineering, Ship Technology
Teachers
Matti Hänninen
Teacher in charge
Matti Hänninen
Groups
MIKT21SP
Marine Engineering, full-time studies
MIKT23KA
Marine Engineering, full-time studies
Course
MI00DR69

Realization has 11 reservations. Total duration of reservations is 65 h 0 min.

Time Topic Location
Wed 11.09.2024 time 08:15 - 16:15
(8 h 0 min)
Kylmätekniikka MI00DR69-3003
B2022_uusikampus Debriefing-suurryhmätila (53)
Thu 12.09.2024 time 09:00 - 15:00
(6 h 0 min)
Käytäntö koko ryhmä. : Kylmätekniikka MI00DR69-3003
Ekami, malminki
Thu 19.09.2024 time 09:00 - 15:00
(6 h 0 min)
Teoria, koko ryhmä: Kylmätekniikka MI00DR69-3003
Ekami, malminki
Fri 20.09.2024 time 09:00 - 15:00
(6 h 0 min)
Teoria, koko ryhmä: Kylmätekniikka MI00DR69-3003
Ekami, malminki
Mon 23.09.2024 time 08:00 - 14:00
(6 h 0 min)
Käytäntö, ryhmä 1: Kylmätekniikka MI00DR69-3003
Ekami, malminki
Mon 23.09.2024 time 14:00 - 20:00
(6 h 0 min)
Käytäntö, ryhmä 2: Kylmätekniikka MI00DR69-3003
Ekami, malminki
Tue 24.09.2024 time 08:00 - 14:00
(6 h 0 min)
Käytäntö, ryhmä 1: Kylmätekniikka MI00DR69-3003
Ekami, malminki
Tue 24.09.2024 time 14:00 - 20:00
(6 h 0 min)
Käytäntö, ryhmä 2: Kylmätekniikka MI00DR69-3003
Ekami, malminki
Sat 05.10.2024 time 08:00 - 14:00
(6 h 0 min)
Käytäntö, ryhmä 3: Kylmätekniikka MI00DR69-3003
Ekami, malminki
Wed 09.10.2024 time 08:00 - 11:00
(3 h 0 min)
Rästit, uusintakoe: Kylmätekniikka MI00DR69-3003
Ekami, malminki
Sat 12.10.2024 time 08:00 - 14:00
(6 h 0 min)
Käytäntö, ryhmä 3: Kylmätekniikka MI00DR69-3003
Ekami, malminki
Changes to reservations may be possible.

Objective

Knowledge and understanding of and proficiency in:
- refrigeration process
- most common refrigerants; properties and environmental safety
- main components of refrigeration plant; design and operation
- direct and indirect cooling circuits; operation and design
- maintenance and fault detection of refrigeration plants

Content

- refrigeration processes
- h/s -diagrams for refrigerants
- refrigerants
- compressors, condensers, tanks, expansion valves, evaporators, subcooler
- piping; equipment and insulation
- process control equipment
- melting, drying
- filling of refrigerant
- lubrication oils of refrigerant plant
- refrigeration containers
- environmental safety
- operation of plant

Course material

The studies for qualification are carried out by the partner.

Study forms and methods

Scheduled track:
You will attend teaching and guidance sessions as specified in the schedule. 100% attendance required.

Independent track:
Not applicable

Blended track:
Not applicable

RDI and work-related cooperation

There are no ECTS points for RDI or working life co-operation in the course.

Timing of exams and assignments

Competence will be evaluated at the demonstration event in accordance with the evaluation criteria of the "handling of refrigerants" part of the qualification part of the building engineering professional qualification.

Course part description

The course includes the part of the degree in the field of refrigeration installation, which is part of the professional degree in building services engineering: "handling of refrigerants".

Students complete theoretical studies and evidence related to refrigerant handling as defined in the national degree criteria at partners workshops. Completion of a part of the degree is accompanied by an exam ensuring theoretical competence in accordance with the course description.

Further information

With a combination of a degree in refrigerant handling, a completed engineering degree and suitable work experience, you can apply for the personal qualification of a person in charge of the refrigeration industry from the Finnish Safety and Chemicals Agency TUKES.

Evaluation scale

Approved/Failed

Assessment methods and criteria

The student demonstrates his / her professional skills on display in various practical work tasks related to refrigerant handling in a real work environment. To the extent that the professional competence required in the part of the degree cannot be assessed on the basis of evidence, the demonstration of professional competence will be supplemented individually in other ways.

Go back to top of page